Question: which is the specific function of PVC – KANAL system?
Answer: it is a PVC push-fit sewage system in brick red colour with a high resistance to chemical substances and low temperature.

Question: why pipes are made of 3 layers, as they are put underground and therefore it’s not a matter of noise-proofing?
Answer: the layers increase the strength of the pipes against impacts occuring sometimes while breaking the ground and laying operations.


ROTSTRICHROHR    MAKE A QUESTION
Question: which reliability is provided by the pre-fixed lip ring seal in terms of wet seal?
Answer: the socket has been designed in order to satisfy requirements of resistance at low pressure (from 0 up to 4 bars). The pre-fixed lip ring seal is the result of the best material and technology available in the world, it is certified by the most important international bodies and has a life comparable to the one of the pipes and the fittings.

Question: is it necessary to use expansion sockets?
Answer: no, just keep the pipe about 1 cm out from the end of the socket while connecting. Polypropylene has a low expansion coefficient and each socket serves as expansion socket.

Question: is the connection with other sewage systems, like HDPE and PVC, possible? And how?
Answer: yes, thanks to the push-fit socket into which it is possible to connect HDPE and PVC pipes in the same diameter, after cleaning, flaring and lubricating the pipe end. To connect pipes in diameters which are not according to PP program, suitable fittings with ring seal should be adopted (any information is available in the technical catalogue).


BAMPLAST    MAKE A QUESTION
Question: is it necessary to use expansion sockets?
Answer: no, just keep the pipe about 1 cm out from the end of the socket while connecting. Polypropylene has a low expansion coefficient and each socket serves as expansion socket.

Question: which reliability is provided by the pre-fixed lip ring seal in terms of wet seal?
Answer: the socket has been designed in order to satisfy requirements of resistance at low pressure (from 0 up to 4 bars). The pre-fixed lip ring seal is the result of the best material and technology available in the world, it is certified by the most important international bodies and has a life comparable to the one of the pipes and the fittings.

Question: is the connection with other sewage systems, like HDPE and PVC, possible? And how?
Answer: yes, thanks to the push-fit socket into which it is possible to connect HDPE and PVC pipes in the same diameter, after cleaning, flaring and lubricating the pipe end. To connect pipes in diameters which are not according to PP program, suitable fittings with ring seal should be adopted (any information is available in the technical catalogue).


POLOKAL NG    MAKE A QUESTION
Question: why Polo-kal NG is in blue colour?
Answer: when in 1995 we started introducing Polo-kal NG system, consisting of 3 layers pipes and mineral reinforced fittings giving high mechanical resistance and noise proof to the system, it was decided to adopt a colour which was original then and easily recognizable as a product from Bampi by dealers and plumbers who nowadays know it very well.

Question: what is the range of sizes of Polo-kal NG?
Answer: Polo-kal NG is available in the diameters 32, 40, 50, 75, 90, 110, 125, 160, 200, 250 mm.

Question: is it possible to repair pipes and fittings which have been bored by a drill?
Answer: yes, with a hole patch weldable by means of a polyfusion machine and the suitable repairing set or by means of a suitable phon. The same hole patches can be utilized also for Polo-kal 3S.


POLOKAL 3S    MAKE A QUESTION
Question: how can You state that Polo-kal 3S is the most noise-proof drainage system on the market?
Answer: the high performance in terms of noise-proofing was tested by the Fraunhofer Institute in Stuttgard (details are specified in the technical catalogue), the important Body certifying most of noise-proof drainage systems.

Question: how could You reach so high noise-proofing levels?
Answer: by working both on the increase of the mass and the pipe layers: a suitable weight reduces the aerial component of the noise while the 3 layers, whose the one in the middle is viscoelastic, absorb the vibrating energy.

Question: is there any law according to which noise-proof drainage systems are required in many-storied buildings?
Answer: yes, the law issued on December, 5 1997 (D.P.C.M. 5/12/1997) provides that noise coming from technical plants, sewage networks included, must be lower than 35 dB (A) in the neighbouring space.


PE-HD    MAKE A QUESTION
Question: is the installation of HDPE drainage systems difficult?
Answer: a particular equipment (welding mirror and electro welding control) is required as well as a particular care in bevelling the fittings and/or the pipes before welding. Moreover it takes care in arranging the expansion sockets, which are necessary to compensate the important variations of PE dimensions.

Question: it is possible to install the HDPE outside?
Answer: HDPE is unbreakable even at low temperature, very resistant to UV beams (for a long life it would be better to not expose it to the sun) and weatherproof.


GREENTHERM    MAKE A QUESTION
Question: on the market there are several PP-R systems with different colours (green, blue etc.): is the colour an important technical feature?
Answer: no, it is just a matter of trading strategy. PP is originally colourless. However the several products present on the market are different in the pureness of the raw material, resistance to pressure of pipes and fittings and sturdiness of brass inserts. It is advised not to weld together products with different brand.

Question: it is advised not to install PP-R just outside boilers, isn’t it?
Answer: yes, because PP-R suffers too high and sudden thermal changes and in case of failure in the safety system of a boiler, some damages could occur.


BALPEX    MAKE A QUESTION
Question: is the use of screw fittings allowed in chased pipes plants?
Answer: no, their use is allowed only in external installations. In chased pipes plants only press-fittings system is allowed.

Question: which kind of jaw is suitable for BALPEX press fittings?
Answer: Bampi’s jaws are “TH” type (one of the most used on the market).


PAVIBALPED    MAKE A QUESTION
Question: does warmth coming from the floor provide an unpleasant sensation?
Answer: floor heating systems made starting from the eighties work with low temperature water (about 35°C) and make the control of all the rooms very easy through the thermostat. Moreover we design our plants according to the UNI EN 1264 stating the ideal parameters (floor temperature included) for a best result in terms of comfort, economy and safety for the end user.

Question: what is the suitable floor thickness?
Answer: 8/9 cm. in average (finishing floor excepted) even if it is possible, if requested, to make it with 6 cm. thickness by using the proper insulation panel and concrete.

Question: what does floor cooling system mean?
Answer: during summer season, by means of suitable components, it is possible to use the same plant for cooling; in this way floors absorb warmth from things and people inside the rooms, avoiding the unpleasant currents of air typical of air-conditioners.


GALLEGGIANTE MAGNETIC    MAKE A QUESTION
Question: what does “noiseproof filling valve” mean?
Answer: the new filling valves, so called “a membrana”, work good mechanically (hydraulic opening and closing) but are noisy because water, during loading, go out from the upper part of the valve by causing the maddening noise with effect “waterfall” for the time it takes to fill the cistern (a 9 litres flush cistern takes about 1 minute to be full!). Even Magnetic has a “membrana” opening and closing system but, thanks to the patented magnet functioning, water filling happens only from the bottom of the cistern, embedded, while a special flush control avoids water hammers without shortening the time to fill the cistern.


Question: can Magnetic be installed only inside exposed cisterns or also inside the built-in type?

Answer: the small dimension and the reversibility of the screw setting the water level allow it to be used in almost all the flush cisterns which have been installed in Italy for 30 years up Today, independently on the water connection side.To be fitted to the built-in flush cisterns, Magnetic is supplied with a kit including an extension pipe made of copper, which can be cut at the required size, and all the components to fix it.It can also be used in ceramic monobloc flush cisterns having the water connection on the bottom, still used in some areas in Italy, thanks to a special kit.


Question: by letting You know the manufacturer’s brand of our very noisy flush cistern, could You assure us that Magnetic can be fitted inside it, by definitively solving the problem of noise?
Answer: the manufacturer’s brand is not enough. We also need to know the exact model and then we inform You whether and how it is possible to install Magnetic. In case of very old flush cisterns (more than 30 years old) or not much used in Italy, we could need to get know of some further dimensional data to be able to give any assurance (our technical dept. is at Your disposal for any information)


BAMSIF    MAKE A QUESTION
Question: how could bad smells coming from air-conditioners be avoided during periods when they do not work?
Answer: generally suitable condensation drain traps should be installed (see in page 20).


POZZETTO CON GUAINA    MAKE A QUESTION
Question: i have to arrange a floor drain trap, which should be built-in on the floor; is there a waterproof system avoiding seepages between trap and sheath, towards the room below?
Answer: yes, we can provide You with PVC slabs in the required dimension, to which we solder a PVC trap complete with siphon, stainless steel grill and contour, so that it is ready to be laid on the raw floor and covered with concrete and finishing.


BAMFLEX    MAKE A QUESTION
Question: is it necessary to insulate gas pipes also through the floor?
Answer: no, but the concrete which cover gas pipes must be gasproof.. Some technician however suggest to use the gas pipe sheath in order to protect the pipes from chemical substances and mechanical damages caused by possible building settling.

Question: is it possible to use also small pieces remaining from the installations, which otherwise should be discarded?
Answer: yes, it is possible only with the PP extensible sheath, by soldering the pieces through a polyfusion machine for HDPE.


BAMSPLIT    MAKE A QUESTION
Question: how does BAMSPLIT function?
Answer: BAMSPLIT is used to discharge the air conditioners condense.

Question: what is the available sizes range?
Answer: the “spiralled” type is available in diameters 16, 18 and 20 mm; the type “with coupling” is available in size 20 mm.